Analysis of common faults of four-column hydraulic press

Generally speaking, if the hydraulic press fails, it is the first time to contact the manufacturer to solve it. But sometimes the machine may just have a little bit of a fault, instead of waiting for the maintenance personnel to come to the door, it is better to try to solve it yourself!


The article I share with you today is to teach you to solve the problems and solutions that may be encountered in the daily use of the four-column hydraulic press!


Follow us, more hydraulic press knowledge is waiting for you to come and see~


四柱液壓機(jī)-YZ32SM-500T.jpg

Zhengxi Group
2023 05 23


Fault 1: The needle of the pressure gauge swings badly


Settle:


1. There is air in the oil circuit of the pressure gauge


2. Mechanical vibration of pipelines


3. The pressure gauge is damaged


Fault 2: Slider crawling problem


Settle:


1. Air is stored in the system or the pump is sucked out


2. Improper precision adjustment or lack of oil in the column


3. Check whether the suction pipe of the pump is inlet or not, and then move up and down many times and pressurize


4. Add oil to the column and readjust the accuracy


Fault 3: The high-pressure stroke speed is not enough, and the upper pressure is slow


Settle:


1. The flow rate of the high-pressure pump is adjusted too small


2. Pump wear or burns


3. Serious leakage in the system


Fault 4: Failure of action


Settle:


The electrical wiring is not firm or the wrong connection is checked for electricity


Fault 5: After parking, the slider slides down seriously


Settle:


1. Leakage of cylinder port sealing ring


2. The adjustment pressure of the pressure valve is too small or the pressure port is not strict


3. Observe the cylinder port and find that the oil is leaking and deflated


4. Adjust the pressure check valve port


Operational precautions


1. Those who do not understand the structural performance or operating procedures of the machine should not start the machine without authorization;


2. During the working process of the machine, the mold should not be overhauled and adjusted;


3. When the machine finds serious oil leakage or other abnormalities (such as unreliable action, loud noise, vibration, etc.), it should stop and analyze the cause, try to eliminate it, and should not put it into production with illness:


4. Do not use overload or exceed the maximum eccentricity:


5. It is strictly forbidden to exceed the maximum stroke of the slider, and the minimum closing height of the mold shall not be less than 600mm.


6. The grounding of electrical equipment must be firm and reliable:


7. At the end of each day's work: put the slider to the lowest position.